Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Otolaryngol Head Neck Surg ; 161(4): 666-671, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31060451

RESUMO

OBJECTIVE: This study investigated the feasibility of obtaining ear impressions for hearing aids by using 3-dimensional high-resolution computed tomography (HRCT) images. STUDY DESIGN: Case series. SETTING: One referral tertiary center. SUBJECTS AND METHODS: Hearing-impaired adults who were fitted with 1 or 2 behind-the-ear hearing aid(s) and had undergone temporal bone HRCT for various ear pathologies were enrolled in this study. Earmolds were fabricated from the impressions obtained using the conventional ear canal silicone injection technique and the HRCT reconstructed technique. Outer ear canal resonance frequencies and amplitude in open ears and those measured with silicon and HRCT reconstructed earmolds were determined through real-ear gain measurements, including real-ear unaided gain (REUG) and real-ear occluded gain (REOG), for comparison. RESULTS: A total of 50 HRCT reconstructed earmolds were compared with 50 conventional silicon injection earmolds. The average value of open ear canal resonance amplitude (REUG) for each ear was 0.41 to 16.76 dB. No statistically significant difference in resonance amplitude (REOG) was observed between silicon and reconstructed earmolds (paired t test, P > .05). The mean insertion loss (REOG-REUG) at all frequencies also did not differ significantly between the two earmolds (paired t test, P > .05). CONCLUSION: According to our real-ear measurements, acoustic characteristics of the HRCT reconstructed earmolds were compatible with those of the silicone injection earmolds. Despite concerns about increased cost and radiation exposure, the HRCT reconstructed technique is a clinically useful and applicable method and can reduce potential safety complications for difficult cases.


Assuntos
Meato Acústico Externo/diagnóstico por imagem , Auxiliares de Audição , Perda Auditiva/reabilitação , Modelos Anatômicos , Ajuste de Prótese/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Meato Acústico Externo/anatomia & histologia , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional
2.
PLoS One ; 10(3): e0120977, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25835987

RESUMO

Binaural hearing involves using information relating to the differences between the signals that arrive at the two ears, and it can make it easier to detect and recognize signals in a noisy environment. This phenomenon of binaural hearing is quantified in laboratory studies as the binaural masking-level difference (BMLD). Mandarin is one of the most commonly used languages, but there are no publication values of BMLD or BILD based on Mandarin tones. Therefore, this study investigated the BMLD and BILD of Mandarin tones. The BMLDs of Mandarin tone detection were measured based on the detection threshold differences for the four tones of the voiced vowels /i/ (i.e., /i1/, /i2/, /i3/, and /i4/) and /u/ (i.e., /u1/, /u2/, /u3/, and /u4/) in the presence of speech-spectrum noise when presented interaurally in phase (S0N0) and interaurally in antiphase (SπN0). The BILDs of Mandarin tone recognition in speech-spectrum noise were determined as the differences in the target-to-masker ratio (TMR) required for 50% correct tone recognitions between the S0N0 and SπN0 conditions. The detection thresholds for the four tones of /i/ and /u/ differed significantly (p<0.001) between the S0N0 and SπN0 conditions. The average detection thresholds of Mandarin tones were all lower in the SπN0 condition than in the S0N0 condition, and the BMLDs ranged from 7.3 to 11.5 dB. The TMR for 50% correct Mandarin tone recognitions differed significantly (p<0.001) between the S0N0 and SπN0 conditions, at -13.4 and -18.0 dB, respectively, with a mean BILD of 4.6 dB. The study showed that the thresholds of Mandarin tone detection and recognition in the presence of speech-spectrum noise are improved when phase inversion is applied to the target speech. The average BILDs of Mandarin tones are smaller than the average BMLDs of Mandarin tones.


Assuntos
Mascaramento Perceptivo , Inteligibilidade da Fala , Fala , Adolescente , Adulto , Audiometria de Tons Puros , Feminino , Humanos , Masculino , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...